Wax Master II

Waxer

 Troubleshooting

Order Parts Item Code & Name

Wax Master Ⅱ | KDF

Mechanical Support

Power ON/OFF

  1. Press any one of the course buttons, °❹, °❸,°❷,°❶, °❶,°❷,°❸,°❹, for a few seconds.
  2. The selected course lamp illuminates.
  3. Re-press the selected course button to switch off.

Pre-Stored Programs

The following program is pre-installed for each grip. Each program is adjustable:

  • °❶ 50°C
  • °❷ 45°C
  • °❸ 85°C
  • °❹ 23°C

Change Pre-Installed Programs

Example: Change °❷ 45°C of Grip 1 to 60°C

  1. Press °❷ on Function 1. Default value 4 5 is displayed.
  2. Press on the grip to show 6 0 on the display and turn the power off.

Temperature Monitor Ramp

  • Red: Lower than the set temp (heating up)
  • Orange: Almost reach the set temp (temp holding)
  • Green: Higher than the set temp (temp cooling)

When you press, the level varies by 3.

Auto Power OFF

For safety purposes, when you forget to turn off the power or not using the grip button operation for a period of time, Wax Master II functions to switch off automatically. Press any one of the buttons on the grip or controller to stop the chime. 1 hour is set as default value. This default value is revisable.

Change a Default Value of Auto Power Off

  1. Press FUNC + °❷ of grip 2
  2. Display (Left): b F
  3. Display (Right): 1. 0 (Default value 60min)

CONTACT

If you would like to order parts for your machine or have questions,
please contact your dealer directly.